steps

The steps array defines the ordered procedural actions of the protocol. Each item captures intent (action), resources (with or use), parameters, and optional control flow directives.

Field Reference

Field Type Required Units Allowed Types Constraints / Enum Example
id string - string Unique "s_1"
action string - string Controlled action term (e.g., add, incubate, centrifuge) "centrifuge"
with list optional - array[string] Material IDs defined in materials[] ["m_buffer"]
use list optional - array[string] Device IDs defined in devices[] ["d_centrifuge"]
parameters map optional - map Quantitative; units required { speed: 13000 rpm }
execution_mode string optional - enum manual, automated, hybrid "manual"
runtime.status string optional - enum pending, running, completed, failed, skipped, aborted "completed"
documentation_level string optional - enum standard, verbose, audit "standard"
confirm map optional - object Manual checkpoint { required: true, message: "Check clarity" }
repeat map optional - object Loop repetition { count: 3, interval: 5 min }
loop map optional - object While-condition { condition: { variable: "OD600", operator: "<", value: 0.5 } }
branch map optional - object Conditional branch { condition: {...}, then: "s_5", else: "s_6" }

Parameter Guidelines

Quantitative parameters must include units (especially in strict mode). Common keys drawn from the specification:

Key Type Units (examples) Valid Range / Guidance Example
volume number mL, µL 0.1–1000 (context dependent) "1 mL"
time number s, min, h ≥0 "30 min"
duration number s, min, h ≥0 "5 min"
temperature number °C −80–150 "37 °C"
speed number rpm 100–30000 "13000 rpm"
angle number ° 0–360 45
pressure number bar, psi ≥0 "1 bar"
concentration number mol/L, mg/mL ≥0 "5 mM"
mass number g, mg ≥0 "1.2 g"
repetitions integer - 1–1000 3
wavelength number nm 180–1100 405
humidity number % 0–100 60
pH number - 0–14 7.4
flow_rate number µL/min, mL/min ≥0 "500 µL/min"
mix_speed number rpm 0–2000 "800 rpm"
distance number mm, cm ≥0 "5 mm"

Control Blocks

Field Required Keys Behavior
confirm required, message, optional by Inserts a manual checkpoint; execution pauses until the operator acknowledges.
repeat count, optional interval, extras Executes the same step a fixed number of times with optional wait intervals.
loop condition, check_interval, max_duration Continues while a logical condition remains true. Requires explicit exit safeguards.
branch condition, then, else Directs control flow to another step ID depending on a condition outcome.

Define conditions using measurable variables (variable, operator, value). Qualitative statements (“until done”) are rejected.

Execution Metadata

  • execution_mode communicates whether automation or manual operation is expected.
    Use hybrid for human-in-the-loop robotics.
  • runtime.status captures live execution states for digital twins, dashboards, or audit logs.
  • documentation_level can increase verbosity of machine-generated reports (audit for regulated studies).

Best Practices

  • Keep IDs stable and descriptive; prefix steps by phase (prep_1, run_2).
  • Group related operations with dedicated notes or attachments for SOP references.
  • Avoid hidden dependencies-reference every material/device explicitly via with/use.
  • Parameter units should be canonical (SI). If devices operate in alternative units, provide conversions in notes.
  • Use branch sparingly; when complex logic is required consider splitting into multiple Labfiles with explicit transitions.

Validation Notes

  • Controlled vocabularies for action are enforced by the validator’s ontology; invalid verbs raise semantic errors (Axxx codes).
  • Strict mode requires all numeric parameters to carry units; missing units raise Q-class errors.
  • Control blocks must define exit conditions; otherwise deterministic validation fails.
  • Cross-references ensure every with/use item exists, preventing orphaned resources.